Columbia Waste Oil Boilers
|
|
- HOT WATER OR STEAM
- OPTIONAL TANKLESS COIL FOR POTABLE HOT WATER SUPPLY
-
LARGE CLEANOUT DOOR FOR FIRE-SIDE CLEANING
- HEAVY GAUGE INCLINED WATER TUBE DESIGN
- ATTRACTIVE INSULATED JACKET
- HINGED BURNER DOOR FOR EASY ACCESS TO FIRE CHAMBER
- CHOICE OF 3 BURNER/NOZZLE COMBINATIONS TO MATCH YOUR REQUIREMENTS
|
|
|
|
|
|
Waste Oil GPH
|
1.25
|
1.68
|
2.5
|
|
Input BTUH
|
175,000
|
235,000
|
350,000
|
|
Gross Output BTUH (approx.)
|
140,000
|
188,000
|
280,000
|
|
Gross H.P.
|
4
|
6
|
8
|
|
Combustion Volume, Cu. Ft.
|
6.5
|
6.5
|
6.5
|
|
Water Volume, Gals.
|
55
|
55
|
55
|
|
GPM Single Coil Temp Rise 100�F
|
2.2
|
3.3
|
4.4
|
|
Boiler Width, with Controls
|
35.5"
|
35.5"
|
35.5" |
|
Depth, with Burner and Smoke Outlet
|
55"
|
55"
|
55"
|
|
Boiler Height
|
57"
|
57"
|
57"
|
|
Flue Outlet
|
9"
|
9"
|
9"
|
|
Compressed Air Requirements
|
2CFM@ 40 psi
|
2CFM@ 40 psi
|
2CFM@ 40 psi
|
|
Water circulator not included
|
|
|
|
| Burner |
WO-B5 |
WO-B5 |
WO-B5 |
| Boiler Weight (Dry) |
1450 lbs. |
1450 lbs. |
1450 lbs. |
| Total Shipping Weight (approx.) |
1800 lbs. |
1800 lbs. |
1800 lbs. |
- Operating Pressure 15 psi Steam, 30 psi Water
|
-
Electrical Requirements (all models) 115/60 15 Amp (220/50 7.5 Amp also available)
|
-
Fuels: Used crankcase oil, transmission and hydraulic fluids, synthetic oils, and other petroleum based lubricants (any weight combination up to SAE 50 including #1 and #2 fuel oil)
|
-
Agency Listings (all models) ASME stamped, ETLM listed (per UL 796, UL 296A, NFPA 31, 70, and 211)
|
|
Standard Equipment: ASME Boiler, ASME Relief Valve, Waste Oil Burner w/Primary Control, J Pump and Filter Kit, Installation Kit & Manual, Insulated Flush Jacket, Theraltimeter Gauge, Operating and Manual High Limit Aquastats or Pressure Controls, Low Water Cut-Off
|
|